Consumer Protection Report by Kenrico

Analysis Conditions PYMS Sample was analyzed using a Agilent 6890 gas chromatograph in conjunction with a 5975B mass selective detector using a Frontier Laboratories double shot Pyrolyzer model PY3030D. Data acquisition was accomplished using MassHunter software. Sample peaks were compared with over 796,613 reference compounds using the NIST/EPA/NIH mass spectral search program. The following run conditions were applied for gas chromatographic analysis: Sample Size: ~0.7 mg Initial Delay: 2.0 minutes Initial Temperature: 50 ºC Final Temperature: 350 ºC Temperature Ramp Rate 1: 20 ºC per minute Hold Time: 15 minutes Pyrolysis Temperature: 1st pass =100-400 ºC, 2nd pass = 700 ºC Detector Temperature: 315 ºC Injector Split: 80:1 Mass Range: Low Mass = 30 High Mass = 700 Column: Ultra Alloy –PBDE Table 1. Identification of thermal and pyrolysis degradation products (1 and 2 heats) RT (mins) Probable ID CAS # Comment/Common Source Powder in Sachet 1st Heat 2nd Heat 2.125 4,7-Dimethylbenzofuran 28715-26-6 Aromatic/phenolic X 2.736 5-Hydroxymaltol 1073-96-7 Cellulose related X 3.189 5-Hydroxymethylfurfural 67-47-0 Cellulose related X 6.939 3.803 Levoglucosan 498-07-7 Cellulose related X 7.8-12 Alkyl polyethylene glyocol (PEG) compounds (m/z 45, 59, 73, 89, 103, 133, 177) N.A. Surfactant related X 4.57- 9.94 Potential aromatic ester related (m/z 60, 77, 91, 115, 128, 165, 196, 213) N.A. Aromatic fatty acid ester related X

RkJQdWJsaXNoZXIy NDU4NTU=